Assuming you are given the transformer capacity in kVA (kilovolt-amperes), the voltage on the secondary winding (V2), and the impedance of the transformer as a percentage (%Z), you can calculate the primary current (I1) with this formula: I1 = kVA × V2 × %Z / 1000 For example, if you have a 2000 kVA transformer with a secondary voltage of 240 volts and an impedance of 4%, then I1 would be equal to:
- First, determine the maximum capacity of the substation in kVA
- In this case, it is 2000 kVA
- Next, find the transformer rating in MVA
- This can be done by multiplying the kVA rating by 1,000
- In this case, the result would be 2,000 MVA
- Once you have the transformer rating in MVA, divide that number by 1,000 to get the current in amperes (A)
- In this example, that would result in a current of 2 A flowing through the substation
Transformer Sizing Calculation Pdf
When it comes to sizing a transformer, there are many factors to consider. One of the most important is the load rating of the appliance or devices that will be plugged into it. The load rating tells you how much power the device uses and is a major factor in determining the size of transformer you’ll need.
Other important factors include voltage, amperage, and phase.
To calculate the size of transformer you need, start by finding the total wattage of all devices that will be plugged into it. Once you have that number, divide it by the voltage (120 for standard homes in North America).
This will give you the amperage required for your transformer. Finally, determine whether you need a single phase or three phase transformer based on your appliances’ wattage and voltage requirements.
11Kv Current Calculation
Calculating the maximum current that can be carried by 11kV cables is a three-step process. The first step is to calculate the resistance of the cable. The second step is to calculate the impedance of the cable.
The third and final step is to use these values to calculate the maximum current that can be carried by the cable.
The resistance of a conductor is given by: R = resistivity x length / cross sectional area
For 11kV cables, the resistivity is generally between 0.01 and 0.02 ohm-meters.
The length of the conductor is usually in meters, so we will use 1 meter for our calculations. The cross sectional area of 11kV cables ranges from 50mm2 to 185mm2 . We will use 100mm2 for our calculations.
This gives us a resistance value of: R = 0.01 x 1 / 100 = 0.0001 ohm
The impedance of a conductor is given by: Z = square root (L / C)
where L is inductance and C is capacitance.
For 11kV cables, L ranges from 0.005 H/m to 0.015 H/m and C ranges from 10 nF/km to 60 nF/km . We will use 0.01 H/m for L and 20 nF/km for C . This gives us an impedance value of: Z = square root (0.. 01 / 20 x 10^9) = 477 ohms
Now we can calculate the maximum current that can be carried by our 11kV cable using Ohm’s law: I max = V / Z
where V is voltage and Z is impedance . For our calculation, we will assume a voltage of 11 kV .
3 Phase Transformer Calculation Formulas
A three phase transformer is a device that transforms electrical energy from one circuit to another, and it does so using three separate coils. The primary coil receives the incoming voltage, while the secondary coil transfers the voltage to the load. In order for this transform to occur, the number of turns in each coil must be different.
For example, if the primary coil has 100 turns and the secondary coil has 50 turns, then the transformer will have a ratio of 2:1. This means that for every two volts applied to the primary coil, one volt will be induced in the secondary coil.
The most common type of three phase transformer is the delta-wye transformer.
This type of transformer is typically used in industrial applications where there is a need to change both the voltage and frequency of an alternating current (AC). Delta-wye transformers are also used in power distribution systems. The wye side of a delta-wye transformer is typically connected to ground, which provides a return path for currents on all three phases.
There are two main types of three phase transformers: autotransformers and isolation transformers. Autotransformers have their primaries and secondaries wound on a single magnetic core, while isolation transformers have their primaries and secondaries wound on separate magnetic cores. Autotransformers are typically smaller and more efficient than isolation transformers, but they offer less protection from electrical shock because there is only one barrier between the primary and secondary circuits.
When sizing a three phase transformer, engineers must consider many factors such as load current, amount of power loss that can be tolerated, efficiency requirements, size constraints, weight constraints, cost constraints etc… The most important factor in sizing a three phase transformer is probably going to be load current since this will determine how much copper needs to be used in windings and how big/heavythe overall unit will need to be .
Hv Amps to Lv Amps Calculator
If you need to know how many low voltage (LV) amps there are in a high voltage (HV) circuit, you can use this handy calculator. Just enter the values for the HV and LV sides of the circuit, and it will do the rest!
Kva Calculation Formula 3 Phase
If you are looking for a kVA calculation formula for 3 phase circuits, then you have come to the right place. This article will provide you with all the information that you need in order to calculate the kVA of a 3 phase circuit.
The first thing that you need to know is what a kVA is.
A kVA stands for kilovolt-ampere and it is used to measure the power of a electrical circuit. The kVA rating of a circuit tells us how much power the circuit can handle before it starts to break down.
In order to calculate the kVA of a 3 phase circuit, we need to use the following formula:
kVA = (V x I) / 1000
Where: V = Voltage (in volts) I = Current (in amps) 1000 = Constant value needed for conversion purposes
Now that we have our formula, let’s go ahead and plug in some values so that we can see how this works in practice.
Let’s say that we have a 3 phase circuit with a voltage of 240 volts and a current of 30 amps. Using our formula, we would calculate the kVA as follows:
Kva= (240 x 30) / 1000 Kva= 7200 / 1000 Kva= 7.2kVa As you can see, calculating the kVA rating of a 3 phase circuit is pretty simple once you know what formulas to use.
Just remember to always divide by 1000 when using this particular equation.
How to Calculate Transformer Load Capacity
In order to calculate the transformer load capacity, you will need to know the following information:
1. The primary voltage (Vp) of the transformer
2. The secondary voltage (Vs) of the transformer
3. The rated current (I) of the transformer
4. The power factor (PF) of the equipment connected to the secondary side of the transformer
With this information, you can use the following equation to calculate the maximum capacity in kVA that your transformer can handle:
Transformer Capacity(kVA)= Vp x I x 1.732 / 1000 x PF x 0.9
For example, let’s say you have a 120 volt primary and a 240 volt secondary with a 30 amp rating and a power factor of 0.8.
Kva Rating Formula
There are a few different ways to calculate the KVA rating of a transformer. The most common way is to use the following formula:
KVA = (V x I x 1.732) / 1000
Where:
V = Voltage in Volts
I = Current in Amps
1.732 = Constant used in calculation

Credit: electrical-engineering-portal.com
How Do You Calculate Lt Current in a Transformer?
Calculating the long-term current in a transformer is a two-step process. First, you need to calculate the transformer’s impedance, which is a measure of its opposition to electrical current. The second step is to use the impedance and the transformer’s rated voltage to calculate the long-term current.
The first step in calculating the long-term current in a transformer is to calculate its impedance. The impedance of a transformer can be calculated using its inductance and capacitance values. The formula for calculating impedance is:
Z=√(L/C)
where L is inductance and C is capacitance.
The second step in calculating long-term current is to use the transformer’s impedance and rated voltage to calculate the long-term current.
The formula for this calculation is: I=V/Z
where V is voltage and Z is impedance.
How Do You Calculate Fault Current in a Substation?
When it comes to calculating fault current in a substation, there are a few different factors that need to be taken into account. The first is the voltage of the system. This can be either alternating current (AC) or direct current (DC).
The second factor is the impedance of the circuit. This includes both the resistive and inductive components. And lastly, you need to know the transformer ratios for both the primary and secondary sides of the transformer.
Now that we have all of that information, we can start to calculate the fault current. First, we need to find the equivalent impedance of the circuit. This is done by adding up all of the individual impedances in parallel.
Once we have that value, we can then divide it into either the voltage of the system (for AC calculations) or into the transformer ratio (for DC calculations). This will give us our final answer for fault current in amperes.
So let’s say, for example, that we have a 230 kV AC system with a total impedance of 15 ohms.
How Many Amps is a 100Kva Transformer?
How many amps is a 100kva transformer?
The answer to this question depends on the voltage of the transformer. A 100 kVA (kilovolt-ampere) transformer can be either single-phase or three-phase.
If it is a three-phase transformer, then it will have a current rating of approximately 833 amps. If it is a single-phase transformer, then its current rating will be lower, around 278 amps.
What is the Current Rating of 200 Kva Transformer?
The current rating of a 200 kVA transformer is 5,500 amps.
transformer full load current calculator| transformer current formula | kva to amps| electrical
Conclusion
If you need to calculate the lt current of a 2000kva substation, there is a simple equation that you can use. First, you will need to know the voltage of the substation. Next, you will need to multiply the voltage by the square root of 3.
Finally, you will divide this number by 1000. This will give you the lt current in amps.